Immagine |
Numero di parte |
Produttore |
Descrizione |
pacchetto |
Azione |
Quantità |
Switching Temperature | Reset Temperature | Current Rating - AC | Current Rating - DC | Tolerance | Switching Cycles | Termination Style | Mounting Type | Package / Case |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Honeywell Sensing and Productivity Solutions |
HERMETIC THERMOSTAT
|
pacchetto: - |
Azione4.338 |
|
- | - | 3A (240V), 7A (30V) | 7A (30V) | - | 5K | - | - | - |
||
Honeywell Sensing and Productivity Solutions |
HERMETIC THERMOSTAT
|
pacchetto: - |
Azione6.336 |
|
- | - | 1.5A (240V), 6A (30V) | 6A (30V) | - | 5K | - | - | - |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder with Mounting Flange |
Azione2.196 |
|
- | - | 7.2A (277V), 15A (120V) | - | - | 100K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder with Mounting Flange |
Azione6.138 |
|
- | - | 7.2A (277V), 15A (120V) | - | - | 100K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder with Mounting Flange |
Azione4.266 |
|
- | - | 7.2A (277V), 15A (120V) | - | - | 100K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Honeywell Sensing and Productivity Solutions |
CERAMIC MANUAL RESET THERMOSTAT
|
pacchetto: - |
Azione7.686 |
|
- | - | - | - | - | - | - | - | - |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder with Mounting Flange |
Azione7.668 |
|
- | - | 7.2A (277V), 15A (120V) | - | - | 100K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder |
Azione5.238 |
|
- | - | - | - | - | - | Quick Connect | Chassis Mount | Cylinder |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder |
Azione2.682 |
|
- | - | - | - | - | - | Quick Connect | Chassis Mount | Cylinder |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder with Mounting Flange |
Azione6.390 |
|
- | - | 7.2A (277V), 15A (120V) | - | - | 100K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Honeywell Sensing and Productivity Solutions |
PHENOLIC AUTO RESET THERMOSTAT
|
pacchetto: Cylinder |
Azione5.814 |
|
- | - | 7.2A (277V), 15A (120V) | - | - | 100K | Quick Connect | Chassis Mount | Cylinder |
||
Honeywell Sensing and Productivity Solutions |
CERAMIC MANUAL RESET THERMOSTAT
|
pacchetto: - |
Azione4.536 |
|
- | - | 8A (120V) | - | - | 100K | - | - | - |
||
Honeywell Sensing and Productivity Solutions |
MANUAL RESET THERMOSTAT
|
pacchetto: Cylinder |
Azione4.086 |
|
- | Manual Reset | - | - | - | - | Solder Lug | Chassis Mount | Cylinder |
||
Honeywell Sensing and Productivity Solutions |
MANUAL RESET THERMOSTAT
|
pacchetto: Cylinder |
Azione2.880 |
|
- | Manual Reset | - | - | - | - | Solder Lug | Chassis Mount | Cylinder |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder |
Azione3.546 |
|
- | - | - | - | - | - | Quick Connect | Chassis Mount | Cylinder |
||
Honeywell Sensing and Productivity Solutions |
CERAMIC MANUAL RESET THERMOSTAT
|
pacchetto: Module |
Azione5.868 |
|
- | - | - | - | - | - | Quick Connect | Chassis Mount | Module |
||
Honeywell Sensing and Productivity Solutions |
MANUAL RESET THERMOSTAT
|
pacchetto: Cylinder with Mounting Flange |
Azione6.102 |
|
- | Manual Reset | 10A (240V), 15A (120V) | - | - | 6K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Honeywell Sensing and Productivity Solutions |
MANUAL RESET THERMOSTAT
|
pacchetto: Cylinder with Mounting Flange |
Azione8.370 |
|
- | Manual Reset | 10A (240V), 15A (120V) | - | - | 6K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder with Mounting Flange |
Azione4.860 |
|
- | - | 10A (240V), 15A (120V) | - | - | 100K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Honeywell Sensing and Productivity Solutions |
CERAM AUTO RESET THERMOSTAT
|
pacchetto: Module |
Azione4.626 |
|
- | - | 10A (240V), 15A (120V) | - | - | 100K | Quick Connect | Chassis Mount | Module |
||
Sensata Technologies/Airpax |
THERMOSTAT 85 DEG NC 8-DIP
|
pacchetto: 8-DIP (0.300", 7.62mm), 4 Leads |
Azione8.928 |
|
185µF (85°C) | 131µF (55°C) | 1A (120V) | 1A (48V) | ±9µF (±5°C) | 25K | PC Pins | Through Hole | 8-DIP (0.300", 7.62mm), 4 Leads |
||
Sensata Technologies/Airpax |
THERMOSTAT 90 DEG NO 8-DIP
|
pacchetto: 8-DIP (0.300", 7.62mm), 4 Leads |
Azione6.372 |
|
194µF (90°C) | 140µF (60°C) | 1A (120V) | 1A (48V) | ±9µF (±5°C) | 25K | PC Pins | Through Hole | 8-DIP (0.300", 7.62mm), 4 Leads |
||
Sensata Technologies/Airpax |
THERMOSTAT 95 DEG NO 8-DIP
|
pacchetto: 8-DIP (0.300", 7.62mm), 4 Leads |
Azione4.464 |
|
203µF (95°C) | 140µF (60°C) | 1A (120V) | 1A (48V) | ±9µF (±5°C) | 25K | PC Pins | Through Hole | 8-DIP (0.300", 7.62mm), 4 Leads |
||
Sensata Technologies/Airpax |
THERMOSTAT 90 DEG NO 8-DIP
|
pacchetto: 8-DIP (0.300", 7.62mm), 4 Leads |
Azione4.518 |
|
194µF (90°C) | 140µF (60°C) | 1A (120V) | 1A (48V) | ±9µF (±5°C) | 25K | PC Pins | Through Hole | 8-DIP (0.300", 7.62mm), 4 Leads |
||
Sensata Technologies/Airpax |
THERMOSTAT 130 DEG NO TO-220
|
pacchetto: TO-220-2 |
Azione3.402 |
|
266µF (130°C) | 194µF (90°C) | - | 0.5A (48V) | ±9µF (±5°C) | 20K | PC Pins | Through Hole | TO-220-2 |
||
Cantherm |
THERMOSTAT 100 DEG C N/O FASTON
|
pacchetto: Cylinder with Mounting Flange |
Azione7.506 |
|
212µF (100°C) | - | 10A (250V), 15A (125V) | 10A (24V), 15A (12V) | ±9µF (±5°C) | 100K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Honeywell Sensing and Productivity Solutions |
AUTO RESET THERMOSTAT
|
pacchetto: Cylinder with Mounting Flange |
Azione3.204 |
|
- | - | 7.2A (277V), 15A (120V) | - | - | 100K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |
||
Cantherm |
THERMOSTAT 90 DEG C N/O FASTON
|
pacchetto: Cylinder with Mounting Flange |
Azione7.968 |
|
194µF (90°C) | - | 10A (250V), 15A (125V) | 10A (24V), 15A (12V) | ±9µF (±5°C) | 100K | Quick Connect | Chassis Mount | Cylinder with Mounting Flange |