Pagina 39 - Prodotti Bourns Inc. - Scaricatori per tubo a scarica di gas (GDT) | Heisener Electronics
Contattaci
SalesDept@heisener.com +86-755-83210559-836
Language Translation

* Please refer to the English Version as our Official Version.

Prodotti Bourns Inc. - Scaricatori per tubo a scarica di gas (GDT)

Record 1.289
Pagina  39/47
Immagine
Numero di parte
Produttore
Descrizione
pacchetto
Azione
Quantità
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Fail Short
Mounting Type
Package / Case
SA2-6200-CBB-STD
Bourns Inc.

GDT 6200V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 6200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione4.392
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
SA2-5500-CBB-STD
Bourns Inc.

GDT 5500V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 5500V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione7.794
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
SA2-3000-CBB-STD
Bourns Inc.

GDT 3000V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 3000V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione2.106
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
SA2-7200-CLB-STD
Bourns Inc.

GDT 7200V 5KA 2 POLE

  • Voltage - DC Spark Over (Nom): 7200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione4.788
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
SA2-3600-CLB-STD
Bourns Inc.

GDT 3600V 5KA 2 POLE

  • Voltage - DC Spark Over (Nom): 3600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione5.148
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
SA2-2400-CLB-STD
Bourns Inc.

GDT 2400V 5KA 2 POLE

  • Voltage - DC Spark Over (Nom): 2400V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione8.100
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
SA2-7200-DLT-STD
Bourns Inc.

GDT 7200V -15%, +20% 5KA T/H

  • Voltage - DC Spark Over (Nom): 7200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: -15%, +20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione6.930
5000A (5kA)
-15%, +20%
2
No
Through Hole
Axial Cylinder
SA2-6300-DLT-STD
Bourns Inc.

GDT 6300V -15%, +20% 5KA T/H

  • Voltage - DC Spark Over (Nom): 6300V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: -15%, +20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione8.280
5000A (5kA)
-15%, +20%
2
No
Through Hole
Axial Cylinder
SA2-6200-DLT-STD
Bourns Inc.

GDT 6200V -15%, +20% 5KA T/H

  • Voltage - DC Spark Over (Nom): 6200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: -15%, +20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione4.500
5000A (5kA)
-15%, +20%
2
No
Through Hole
Axial Cylinder
SA2-5500-DLT-STD
Bourns Inc.

GDT 5500V -15%, +20% 5KA T/H

  • Voltage - DC Spark Over (Nom): 5500V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: -15%, +20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione3.240
5000A (5kA)
-15%, +20%
2
No
Through Hole
Axial Cylinder
SA2-3600-DLT-STD
Bourns Inc.

GDT 3600V -15%, +20% 5KA T/H

  • Voltage - DC Spark Over (Nom): 3600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: -15%, +20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione6.336
5000A (5kA)
-15%, +20%
2
No
Through Hole
Axial Cylinder
SA2-3000-DLT-STD
Bourns Inc.

GDT 3000V -15%, +20% 5KA T/H

  • Voltage - DC Spark Over (Nom): 3000V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: -15%, +20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione8.802
5000A (5kA)
-15%, +20%
2
No
Through Hole
Axial Cylinder
SA2-2400-DLT-STD
Bourns Inc.

GDT 2400V -15%, +20% 5KA T/H

  • Voltage - DC Spark Over (Nom): 2400V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: -15%, +20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione2.628
5000A (5kA)
-15%, +20%
2
No
Through Hole
Axial Cylinder
hot 2020-42T-C4LF
Bourns Inc.

GDT 360V 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 360V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Radial Cylinder, 3 Lead
pacchetto: Radial Cylinder, 3 Lead
Azione15.432
10000A (10kA)
-
3
No
Through Hole
Radial Cylinder, 3 Lead
2020-23T-C4FLF
Bourns Inc.

GDT 180V 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 180V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Radial Cylinder, 3 Lead
pacchetto: Radial Cylinder, 3 Lead
Azione3.186
10000A (10kA)
-
3
Yes
Through Hole
Radial Cylinder, 3 Lead
2020-15T-C4FLF
Bourns Inc.

GDT 60V 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 60V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Radial Cylinder, 3 Lead
pacchetto: Radial Cylinder, 3 Lead
Azione7.740
10000A (10kA)
-
3
Yes
Through Hole
Radial Cylinder, 3 Lead
2020-23T-C2FLF
Bourns Inc.

GDT 180V 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 180V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
pacchetto: Axial Cylinder, 3 Lead (Radial Bend)
Azione6.084
10000A (10kA)
-
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2020-15T-C2FLF
Bourns Inc.

GDT 60V 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 60V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
pacchetto: Axial Cylinder, 3 Lead (Radial Bend)
Azione8.424
10000A (10kA)
-
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
SA2-3600-CK1B-STD
Bourns Inc.

GDT 3600V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 3600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione7.794
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2030-42T-SMLF
Bourns Inc.

GDT 360V 4KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 360V
  • Impulse Discharge Current (8/20µs): 4000A (4kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
pacchetto: 3-SMD Cylinder Square End
Azione3.544
4000A (4kA)
-
3
No
Surface Mount
3-SMD Cylinder Square End
SA2-4500-CLT-STD
Bourns Inc.

GDT 4500V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 4500V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione4.860
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
SA2-2400-CLT-STD
Bourns Inc.

GDT 2400V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 2400V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione8.784
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2020-42T-A1LF
Bourns Inc.

GDT 360V 10KA

  • Voltage - DC Spark Over (Nom): 360V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
pacchetto: Cylinder No Lead, 3 Terminal
Azione5.958
10000A (10kA)
-
3
No
User Defined
Cylinder No Lead, 3 Terminal
2026-35-A1FLF
Bourns Inc.

GAS DISCHARGE TUBE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
pacchetto: Cylinder No Lead, 3 Terminal
Azione7.398
20000A (20kA)
±20%
3
Yes
User Defined
Cylinder No Lead, 3 Terminal
2036-60-B2FLF
Bourns Inc.

GDT 600V 10KA 3 POLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
pacchetto: Axial Cylinder, 3 Lead (Radial Bend)
Azione4.176
10000A (10kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2026-40-CF
Bourns Inc.

GDT 400V 20KA 3 POLE

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
pacchetto: Axial Cylinder, 3 Lead (T-Shape)
Azione3.204
20000A (20kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
2026-09-A1FLF
Bourns Inc.

GDT 90V 20KA 3 POLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: User Defined
  • Package / Case: Cylinder 1 Lead, 3 Terminal
pacchetto: Cylinder 1 Lead, 3 Terminal
Azione7.236
20000A (20kA)
±20%
3
Yes
User Defined
Cylinder 1 Lead, 3 Terminal
2026-60-C3FLF
Bourns Inc.

GDT 600V 20% 20KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
pacchetto: Axial Cylinder, 3 Lead (Radial Bend)
Azione5.508
20000A (20kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)