Pagina 14 - Prodotti Bourns Inc. - Scaricatori per tubo a scarica di gas (GDT) | Heisener Electronics
Contattaci
SalesDept@heisener.com +86-755-83210559 ext. 805
Language Translation

* Please refer to the English Version as our Official Version.

Prodotti Bourns Inc. - Scaricatori per tubo a scarica di gas (GDT)

Record 1.289
Pagina  14/47
Immagine
Numero di parte
Produttore
Descrizione
pacchetto
Azione
Quantità
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Fail Short
Mounting Type
Package / Case
2035-30-B5LF
Bourns Inc.

GDT 300V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 300V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione6.264
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-23-B5LF
Bourns Inc.

GDT 230V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione3.780
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-20-BT1LF
Bourns Inc.

GDT 200V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione7.254
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-15-BT1LF
Bourns Inc.

GDT 150V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione7.308
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-15-B5LF
Bourns Inc.

GDT 150V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione5.652
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-60-B5
Bourns Inc.

GDT 600V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione6.858
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-40-B5
Bourns Inc.

GDT 400V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione6.894
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-35-BT1LF
Bourns Inc.

GDT 350V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione8.982
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-35-BT1
Bourns Inc.

GDT 350V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione6.750
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-35-B5
Bourns Inc.

GDT 350V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione5.238
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-30-B5
Bourns Inc.

GDT 300V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 300V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione8.748
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-25-B5
Bourns Inc.

GDT 250V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione8.802
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-23-BT1
Bourns Inc.

GDT 230V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione8.082
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-20-B5
Bourns Inc.

GDT 200V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
pacchetto: Axial Cylinder, Radial Bend
Azione5.598
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder, Radial Bend
2035-15-BT1
Bourns Inc.

GDT 150V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione6.714
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2035-09-BT1
Bourns Inc.

GDT 90V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione3.528
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2035-09-B5
Bourns Inc.

GDT 90V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione4.464
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2037-40-BLF
Bourns Inc.

GDT 400V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione2.502
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-47-BLF
Bourns Inc.

GDT 470V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione4.932
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-42-BLF
Bourns Inc.

GDT 420V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione8.586
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-23-BLF
Bourns Inc.

GDT 230V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione2.430
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-60-B
Bourns Inc.

GDT 600V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione2.412
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-42-B
Bourns Inc.

GDT 420V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione4.554
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-35-B
Bourns Inc.

GDT 350V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione5.274
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-30-B
Bourns Inc.

GDT 300V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 300V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione2.988
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-25-B
Bourns Inc.

GDT 250V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione6.696
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-23-B
Bourns Inc.

GDT 230V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione7.398
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-20-B
Bourns Inc.

GDT 200V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione5.706
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder